TRI-ONE UPS
- Thanks to its high performance, Tri-One series provides the best protection for any kind of application and load
- Through its LCD display it is possible to control all parameters and functions
- Moreover, it is possible to remotely control the UPS by means of the SNMP card
- Tri-One series use a smart recharge control for the battery, in order to increase their lifetime (see picture below)
- In fact, batteries are charged at three different steps, increasing their performance and life, and reduce overall cost
TRI-ONE TMSS – EN50171
- Tri-One TMSS series is designed to be compliant with EN50171 standard
- Main applications are:
* Centralized emergency lighting systems
* Automatic fire extinguishing installations
* Paging systems and signalling safety installations
* Smoke extraction equipment
* Carbon monoxide warning systems
* Specific safety installations related to specific buildings, e.g. high-risk areas
- Our "Elsist Battery Control" system allows the right operation in case of mains outages, checking the conditions of every battery pack
- The battery charger is designed to recharge the batteries at 80% of total capacity in less than 8 hours
- Autonomy times may be 1, 2 or 3 hours at nominal load, according to the condition specified by EN50171 standard
TRI-ONE CF
- 50/60Hz Frequency converter at 6kVA and 10kVA with VFI sinusoidal waveform (Voltage and Frequency Independent)
- Frequency converter supply a linear current and a complete protection to:
* Data Network/PC
* Data center
* Server
* Telecommunication system
* Hospital equipment
* Industrial equipment
* The Frequency converter provides an output at 50Hz or 60Hz which is independent from input frequency
* The Power Factor correction circuit improves the quality of absorbed input current, thus increasing the efficiency and saving energy
Specifications
- Nominal Power: 10KVA / 9KW
INPUT
- Input: Three-phase
- Power Factor: >0.99
- Nominal Frequency: 50Hz/60Hz (Selectable)
- Voltage Range: 208 - 478Vac
- Frequency Range: 45-55Hz (50Hz) - 55-65Hz (60Hz)
- Bypass voltage range:
* 220Vac max:default +25% (+10%, +15%, +20%) optional
* 230Vac max:default +20% (+10%, +15%) optional
* 240Vac max:default +15% (+10%) optional
* min:default -45% (-20%, -30%) optional
- Bypass Frequency Range: +/-1% - +/-2% - +/-4% - +/-5% - +/-10%
BATTERY
- Number Of Batteries: 16 Standard / 18/20 optional (embedded)
- Type: 12V - 9Ah / Maintenance-free Lead-acid (VRLA)
- Charging Type: Fast recharge or floating automatically selected
- Recharging Time: Fast up to 20h (Max)
- Max. Recharging Current: 1A
OUTPUT
- Output: Single-phase
- Voltage Tolerance: +/-1.0%
- Voltage Distortion (THD):
* Less than 2% with 100% linear load
* Less than 5% with 100% non-linear load
- Nominal Voltage: 220V/230V/240Vac +/-1.0%
- Frequency Regulation:
* +/-0.1% (single unit)
* +/-0.25% (more units in parallel)
- Frequency:
* Mains On: same as Mains (Phase A)
* In battery mode: 50Hz / 60Hz +/-0.1Hz
- Frequency Synchronization:
* 1Hz/s (single unit)
* 0.5Hz/s (more units in parallel)
- Overload with Mains present:
* 105% - 110%,for max 1h
* 110% - 125%, for max 10 min
* 125% - 150%, for max 1 min
* >150% switch to bypass
- Overload on bypass:
* Feed the load for long time if output current is below 125%
* Overload on Bypass is limited by the breaker rating
- Crest Factor: 3:1
- Efficiency AC 100%: 93.5%
- Dynamic Response: +/-5% / 40ms
- DC component: <100mV
SWITCH TIME
- From Mains to battery: 0ms
- From inverter to bypass:
* 0ms (synchronous)
* <15ms (50Hz), <13.33ms (60Hz) (asynchronous)
OTHER
- Noise: <55dB (1m)
- Display: LED + LCD
- Safety: Compliant to IEC62040-3
- EMI:
* Conduction:IEC 62040-3
* Radiation:IEC 62040-3
* Armonics:IEC 62040-3
- EMS: IEC 62040-3
- MTBF: 250.000 hours
- Insulating resistance: >2M Ohm (500Vdc)
- Voltage isolation: 2820Vdc, <3.5mA, 1min
- Voltage surge: Compliant to IEC60664-1 1.2/50uS+8/20uS 6KV/3KA
- IP protection grade: IP20
ENVIRONMENT
- Temperature: 0C to 40C (batteries not included)
- Humidity: 0% - 95% non condensing
- Altitude: <1500m if >1500m power is reduced
MECHANICAL
- Dimensions (H×W×D): 655×250×597 mm
- Weight: 76 kg
Trenutno nema komentara za ovaj proizvod. Budite prvi koji će komentirati!
Da bi napisali svoje mišljenje o ovom proizvodu potrebno je imati aktivan račun na našim stranicama!
Možete se registrirati kao novi korisnik ili prijaviti kao već postojeći.
Što se tiče najčešćih razloga odbijanja, to je zasigurno neispravna 3D secure potvrda plaćanja (3D secure verifikacija).
Dakle, da bi kupac uspješno izvršio plaćanje sa karticom, potrebno je na sučelju svoje banke unijeti lozinku koju samo on zna. Ukoliko nije siguran koja mu je lozinka, neka klikne na „Zaboravili ste zaporku“ ili neka nazove helpdesk svoje banke.
3D Secure potvrda plaćanja je obaveza koju je definirala banka izdavatelj kartice radi povećanja sigurnosti plaćanja preko weba, a sa kojom vlasnik kartice treba biti upoznat prilikom plaćanja preko weba. Kao kada u dućanu plaćanje karticom potvrđujete PIN-om kojeg zna samo vlasnik kartice, tako se i plaćanje preko weba potvrđuje preko 3D secure sučelja banke izdavatelja pomoću lozinke, šifre, PIN-a kojeg zna samo vlasnik kartice
Već duže vrijeme u Hrvatskoj za plaćanja putem MasterCard, VISA i Maestro karticama je potrebno izvršiti dodatnu autentifikaciju plaćanja.
Dodatne informacije na stranicama banaka:
PBZ kartice:
http://www.pbzcard.hr/hr/online-usluge/3-d-secure-program/domena-izdavatelja-kartica---3d-secure-issuing
http://www.pbzcard.hr/hr/online-usluge/3-d-secure-program
ZABA kartice:
https://www.zaba.hr/home/podrska/koristenje-kartica-na-internetu
Erste kartice:
https://www.erstecardclub.hr/hr/pogodnosti/visa-mastercard-pogodnosti/sigurna-i-brza-kupnja-na-internetu-zahvaljujuci-3d-standardu-mastercard-securecode
RBA kartice:
https://www.rba.hr/sigurnost-transakcije
Napominjemo da svaka banka ima neka svoja pravila:
Primjer 1: Ukoliko se traži unos PIN-a, to uglavnom nije PIN koji se koristi prilikom dizanja novca sa bankomata, već PIN koji se kreira prilikom uključivanja uređaja koji se koristi kod net-bankinga (token, čitač kartica...) ili se šalje na prijavljeni mobitel korisnika.
Primjer 2: Ukoliko se traži unos broja osobnog dokumenta, npr. osobne iskaznice - ukoliko je kupac u međuvremenu mijenjao osobnu iskaznicu, dok ne prijavi novi broj u banci neće mu biti odobrena 3D verifikacija za online plaćanje sa tom karticom
Primjer 3: neke banke odobravaju prva 3 plaćanja bez 3D verifikacije; za svako sljedeće plaćanje je potrebno unijeti traženi podatak za odobravanje plaćanja
...
NAPOMENA: Kako svaka banka ima svoje odredbe oko toga što je potrebno unijeti za 3D verifikaciju (PIN, lozinku, šifru, broj osobnog dokumenta...), uvijek preporučujemo da provjerite sa svojom bankom što je točno potrebno unijeti kako bi se odobrila 3D verifikacija.